Rated cooling capacity |
Refrigeration Rated Power |
Electric Shock |
Waterproof |
Refrigerant |
50KW |
12 KW |
1 |
IPX4 |
R410A |
Refrigerating Current |
Fan Power |
Air Volume |
Water Pump Power |
|
20A |
2.2KW |
10000m³/h
12000m³/h |
0.75KW |
|
Power Supply |
Internal Size |
External Size |
Weight |
|
380V/3PH/50HZ |
140010002300mm |
162010002150mm |
1000kg |
1.The return air of indoor unit of air - conditioning system adopts double - layer filter net and wet curtain filtration, which filters different particles of dust in stages to protect the cleanliness of evaporator and ensure heat - exchange efficiency and system life.
2.For printing and packaging industry dust, paper wool and powder particle diameter were designed with different mesh filter to achieve effective filtration.
3.High efficiency evaporative condenser, make full use of the physical principle of water evaporation and heat absorption, evaporative condenser system formed by low condensation temperature, so that the compressor running power is small, power consumption is low,EER value can reach more than 4.0 (ordinary air - cooled heat pump air - conditioning EER value 2.3), can realize compressor power - saving operation.
4.After throttling, the low - pressure liquid refrigerant absorbs heat and evaporates, further reducing the inlet air temperature, and the two - stage cooling improves the overall energy efficiency of the air - conditioning system (the comprehensive EER of refrigeration can reach about 4.5). Compared with the traditional air - cooled air conditioner, the energy saving is 45%.